Measured values CO, CO2, NOx, O2, SO2
Performance-tested measurands CO, CO2, NOx, O2, SO2
Measurement principles NDIR spectroscopy, electrochemical cell
Gas flow rate
10 l/min ... 60 l/min
Measuring ranges
CO 0 ... 500 mg/m³ / 0 ... 2,500 mg/m³
NO 0 ... 500 mg/m³ / 0 ... 2,500 mg/m³
O2 0 ... 21 Vol.-%
SO2 0 ... 500 mg/m³ / 0 ... 2,500 mg/m³
Certified measuring ranges
CO 0 ... 2,500 mg/m³
NO 0 ... 2,500 mg/m³
SO2 0 ... 2,500 mg/m³
Response time (t90) ≤ 15 s
Accuracy
≤ ± 1 %
Of measuring range full scale
Sensitivity drift
≤ ± 1 %: of measuring range full scale per week
Zero point drift
≤ ± 1 %: of measuring range full scale per week
Reference point drift
≤ ± 1 %: of measuring range full scale per week
Detection limit
≤ 1 %
Resolution
≤ 1 %
Process temperature
≤ +300 °C
Process pressure
–100 hPa ... 100 hPa
Relative
Ambient temperature
+5 °C ... +35 °C
Storage temperature
–20 °C ... +70 °C
Ambient pressure
900 hPa ... 1,100 hPa
Enclosure rating
IP40
Analog outputs 4 outputs:
4 ... 20 mA
Analog inputs Optional 2 inputs possible
Digital outputs Optional 4 outputs possible
Digital inputs Optional 4 inputs possible
Dimensions (W x H x D)
800 mm x 2,100 mm x 800 mm
Weight
≤ 300 kg
Energy supply
Voltage 220 V AC
Frequency 50 Hz
Power consumption ≤ 2,000 VA
Auxiliaries
Instrument air: ≥ 4 bar ≤ 100 l/min
During backflushing
Sample gas connections
Sample gas inlet 8 mm diameter
Exhaust gas outlet 14 mm diameter
Auxiliary gas connections
Instrument air DN 6/8
Corrective functions Manual or automated adjustment with test gases
System components

Gas sampling unit

Sample gas line

Analyzer cabinet

Connection unit

Integrated components

Temperature sensor

Pressure sensor

Humidity sensor

Flow sensor

SMC900